DC Volts Maximum Input: 1000V Maximum Resolution: 0.1mV Accuracy: +/-0.3%
AC Volts Maximum Input: 750V Maximum Resolution: 0.001V Accuracy: +/-0.75%
DC Amps Maximum Input: 10A Maximum Resolution: 0.1µA Accuracy: +/-0.5%
AC Amps Maximum Input: 10A Maximum Resolution: 0.1µA Accuracy: +/-0.75%
Resistance (Ohms) Maximum Input: 40MΩ Maximum Resolution: 0.1Ω Accuracy: +/-0.5%
Frequency Maximum Input: 200KHz Maximum Resolution: 0.01Hz Accuracy: +/-0.05%
Capacitance Maximum Input: 10000µF Maximum Resolution: 0.01µF Accuracy: +/-2%
Inductance N/A
Temperature (K-Type Thermocouple) N/A
Continuity Audible at less than 100Ω
Diode 3V at 2.5mA maximum output
Duty Cycle N/A
True RMS Responding Yes
Conductance No
Pulse Width No
Data Hold Yes, 2 hold system
Min/Max Record Yes
Time Stamp Logging No
Relative Mode Yes
Compare Mode Yes
RS-232 Output Yes
Process Loop Output No
Sleep Mode / Auto Off Yes
Protective Boot Yes (standard)
Display Type 4,000 count backlit LCD with dual sub displays and analog bargraph
Range Selection Auto / Manual
Operating Temperature 32°F to 113°F (0°C to 40°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Humidity 80% non-condensing
Size 7.4” x 3.4” x 1.2” (187mm x 86mm x 33mm) with boot
Weight 14.4oz (380g) with boot
Battery Type 9V Alkaline (NEDA 1604)
Battery Life 100hrs Typical
Overvoltage Category CAT III 600V
Agency Approval cULus 61010-1, IEC 61010-1
Warranty 3 Years
183 Applications
Thermocouples in furnaces or gas applications
Heat anticipator current in thermostats
Line voltage
Control circuit voltage
Flame safeguard control current
Heating element resistance (continuity)
Compressor winding resistance
Contactor and relay coil resistance
Continuity of wiring
Motor start and run capacitance
Frequency on controls and line voltages
Record min/max voltage of controls and line voltages
Temperature with optional temperature adapter (A310)
Bar graph to indicate rapid fluctuations in measurements
Voltage of direct drive DC motors
Measure power supply voltage
Match components
Compare readings in circuits and components
Frequency of line and control voltage
DMMs FAQs

1. Is there a way to measure higher current with a TPI DMM?

TPI DMMs (except the 120 and 126) have the capacity to read up to 10A AC/DC. Optional adapters are available for all models to increase the current range. Our shunt adapters are available to increase the range up to 1,000A AC/DC.

2. What other adapters are available for TPI DMMs?

Various adapters including carbon monoxide (A771), pressure (A620/630), and clamp-on low current (A254) are available. Contact TPI for additional information.

3. Which of the TPI DMMs will measure temperature?

All TPI DMMs can measure temperature by using the optional A301 K-Type thermocouple temperature adapter.

4. Which TPI DMMs can measure DC millivolts?

All TPI DMMs measure millivolts. Models are available with 1 or 0.1 millivolt resolution.

5. Which TPI DMMs can measure DC microamps?

The TPI 126, 133, 135, 153, 163, 183, 190, 194, 196, and 440 all have this capability.

6. Which TPI DMMs will measure capacitance?

The TPI 135, 183, 190, 192, 194, and 440 all have this capability.

7. What is continuity?

Continuity refers to a test performed on wires and circuits to see if a break(open) exhists. If the wire or circuit is continuous, the resistance reading will be at or near zero. The continuity range on a meter provides audible indication of a continuous circuit, allowing quicker tests without having to take your eyes off the circuit or wire under test.