OWON PDS7102T Oscilloscope

SKU: PDS7102T
Stock: 0
Price:
$541.00

Qty: - +
   - OR -   

Portable dual channel oscilloscope with widened bandwidth, large color display and battery supply. Optimal price-specifications ratio!

Digital storage oscilloscope. Dual channels + external trigger. Bandwidth 100 MHz. Sample rate (Real time) 500MS/s. Record length 6K points on each channel. Cursor measurement. Automeasurement 20 types. Trigger type: Edge, Video, Alternate. FFT. Peak detect and Average. Display: 8.0 '' color LCD, TFT screen, 640×480 pixels. Dimensions: 14in × 6in × 4in / 356mm × 153mm × 102mm. Weight: 3.7lb / 1.7kg

Technical Specifications:

  • This instrument should run for more than 30 minutes continuously under the specified operating temperature.
  • If the change range of the operating temperature is up to or exceeds 41°F / 5°C, open the system function menu and execute the “Auto-calibration” procedure.

All specification standards can be fulfilled, except one(s) marked with the word “Typical”

Sampling

  • ACQU Mode Sample, Detection, Average
  • Sampling Rate: 250 MS/s

Input

  • Input Coupling DC, AC
  • Input Impedance 1MΩ ± 2%, connected with 20pF ± 5pF in parallel
  • Probe attenuation coefficient: 1X, 10X, 100X, 1000X
  • Max. Input Voltage: 300V, Peak Value

Level

  • Sampling Rate Range: 10S/s~250MS/s
  • Waveform interpolation (sinx) /x
  • Record Length 5000 sampling points per channel
  • Scanning Speed Range (S/div): 5ns/div~5s/div, according to the stepping mode of 1- 2- 5

Measuring Accuracy of Time Interval (ΔT) (DC~50M)

Single: ± (One Sampling Interval Time + 100ppm × Reading + 0.6ns) > Averages of 16: ± (One Sampling Interval Time + 100ppm × Reading +0.4ns)

Vertical

  • A/D Converter Resolution of 8 bits, with the sampling carried out in two channels at the same time
  • Sensitivity (Volt/division); Range (V/div): 5mV/div - 5V/div (at the input BNC)
  • Displacement Range ± 50V (500mV - 5V), ± 2V (5mV - 200mV)
  • Simulative Bandwidth: 60M
  • Single Bandwidth, Full Bandwidth
  • Low frequency respond (AC Coupling, - 3dB) ≥ 5Hz (at BNC)
  • Rising Time (Typical, at BNC): ≤ 5.8ns
  • DC Gain Accuracy: ± 5%
  • DC Measuring Accuracy(Average for ACQU MODE)
  • The voltage difference (ΔV) between any two points on the wave form after averaging the captured wave forms of more than 16: ± (5% Reading + 0.05 divisions)

Trigger

Trigger Sensitivity (Edge Trigger)

  • DC Coupling Channel 1 and Channel 2: 1div (DC ~ Full Bandwidth)
  • EXT 100mV (DC - 20M)
  • EXT/5 500mV (DC - 20M)
  • AC Coupling It is the same as the DC coupling in case of 50Hz or more

Trigger Level Range

  • Internal: ± 6 divisions from the screen center
  • EXT ± 600mV
  • EXT/5 ± 3V

Trigger Level Accuracy (Typical): It is applicable to the signal with the rising and falling time ≥ 20ns

  • Inside: ± 0.3 div
  • EXT ± (40mV + 6% of Set Value)
  • EXT/5 ± (200mV + 6% of Set Value)

Trigger Displacement

  • Preliminary Trigger: 655 divisions
  • Late Trigger: 4 divisions

Set Level to 50% (Typical)

Operation under the condition of input signal frequency ≥ 50Hz

Trigger Sensitivity (Video trigger, typical)

  • Internal Peak-to-peak value of 2 divisions
  • EXT 400mV
  • EXT/5 2V

Signal System and Line/Field Frequency (Video Trigger Type)

Supporting the NTSC, PAL and SECAM broadcast system of any field frequency of line frequency

Measurements

Cursor Measurement: Voltage difference (ΔV) and time difference (ΔT) between cursors

Automatic Measurement: Peak-to-Peak Value, Average, RMS, Frequency and Cycle

Probe

  1X Position 10X Position
Bandwidth DC: up to 4 MHz DC: up to full bandwidth
Attenuation Ratio 1: 1 10: 1
Compensation Range 10pf ~ 35pf  
Input Resistance 1MΩ± 2% 10MΩ± 2%
Input Electric Capacity 85pf - 115pf 14.5pf - 17.5pf
Input Voltage 150 V DC 300 V DC

General Technical Specifications:

Display

  • Display Type 8″ TFT LCD (Liquid Crystal Display)
  • Display Resolution 640 (Horizontal) × 480 (Vertical) Pixels
  • Display Colors: 260000 Colors

Output of the Probe Compensator

  • Output Voltage (Typical) About 5V, with the Peak-to-Peak value equal to or greater than 1MΩ of load.
  • Frequency (Typical) Square wave of 1KHz

Power

  • Mains Voltage 100~240 VAC RMS, 50Hz, CAT II
  • Power Consumption < 15W
  • Fuse 1A, T grade, 250V

Environment

  • Temperature Working temperature: 32°F~104°F / 0°C~40°C
  • Storage temperature: -4°F~ +140°F / -20°C~ +60°C
  • Relative Humidity ≤ 90%
  • Operating: 3280yd
  • Non-operating: 27032yd
  • Cooling Method Natural convection

Mechanical Specifications

  • Dimensions: 14in × 6in × 4.7in / 356mm × 153mm × 102mm
  • Weight: 0.16 stone

Interval Period of Adjustment: One year is recommended for the calibration interval period